radiographic quality evaluation


Radiographic Quality Evaluation: Bad Pantomographs (Part 2)

Onto criteria 3 and 4. 3. Frankfort horizontal plane is positioned on the correct anatomical landmarks creating a slight concave occlusal plane. Error: Improper patient positioning of the Frankfort horizontal plane in the unit causing distortion of the final image. Note the V-shaped occlusal plane Correction: Move chin superiorly and […]


Radiographic Quality Evaluation: Bad Pantomographs (Part 1) 1

This week will be covering the first 2 criteria for an ideal pantomograph and what happens to the final image when they are not met. 1. Patient has anterior teeth in notches on bite block. Error: Patient positioned too far anteriorly or posteriorly in the unit creating minification (too far […]


Radiographic Quality Evaluation: Ideal Pantomograph 4

This week I am showing an example of an ideal pantomograph along with 6 criteria that are used when determining the quality of a pantomograph.  The next couple weeks will be showing examples of when those 6 criteria are not met and how to correct them. 1. Patient has anterior […]